lead rubber protective suit
1.Pulled on from the right side and one-faced
2.Good quality, low price
3,OEM
The lead equivalent is: 0.5mmpb.
They are mainly used
for the protection of the X-ray.
Protection range:
1, the radiation in the workplace: X-rays, ¥ã-rays, ¥á surface contamination, ¥â surface contamination;
2, medical radiation equipment: diagnostic X-ray machine, X-ray CT, X-ray digital silhouettes device (DSA), radiation therapy device (cobalt-60 therapy machine, installed after treatment, etc.), medical accelerator ¥Ã knife, X knife, nuclear medicine equipment (SPECT, PET, ¥ã camera, mainly perspective, shooting, fault, dental, orthopedic X-rays and CT protection; Interventional Radiology: Cardiovascular imaging, interventional treatment of protection; simulators, after installed, CO60 treatment machines, linear accelerator, X knife, gamma knife and other protective equipment room.
3, non-medical radiation equipment: non-medical accelerators, radioactive sources, including the source device and radiation devices industrial-ray detection machine, the gamma-ray detection machine, linear accelerator room protection, nuclear gauge, neutron generators, sealed radioactive sources non-sealed radioactive sources, X-ray diffraction, nuclear facilities and radiation devices and other large facilities (nuclear power plants, nuclear reactors, radiation processing unit, the (high) energy accelerator) and other protection.
4, underground non-uranium mining: high levels of radon and its daughters illuminating radiation protection such as coal, non-ferrous metal ore, iron ore, tin and other miners suffer.
[Note]: should lie flat (1) the use or hanging up, not folding, folding in order to avoid long-term cause rupture and drain lines phenomenon;
(2) should be stored at a relative humidity less than 80%, no direct sunlight, away from heat, non-corrosive gases and good indoor ventilation; strictly prohibited and acid, alkali and other items detrimental to the contact with the product in order to prolong its life.
(3) the use of protective equipment for the life of 4-5 years should be checked regularly. Check is hand flat touch or remove the cloth to eyesight observation, if a third of the crack, the product can not be used, must be scrapped
Ray protective clothing
In actual work, due to the limitation of conditions, often short
contact time and increase the distance alone cannot achieve the goal
of safe operation. Install a large indoor 60 Co irradiation source,
for example, were only a few meters from a maximum distance of staff.
Dose equivalent in the staff May 1 / SEC, then stay there for a
second also is very dangerous. So the above two methods are not
applicable, and shielding protection must be used. Shielding
protection is according to the principle of radiation through
material was weakened, between people and the radiation source and a
thick enough layer of the shield (less material), reduce the external
exposure dose to control under the standard, to protect the security
of the human body. Shielding materials according to the different
nature of rays, type